Northwest Well & Septic WA · OR · ID directory

Home · Guides

Bacteria in well water and disinfection

What Washington’s health department recommends when a private well is tested for coliform bacteria, and how official disinfection (shock-chlorination) procedures are published — including the current DOH tables for small water systems and an older Mason County private-well brochure. Disinfection is not a substitute for finding a sanitary defect, and it does not treat nitrate or arsenic.

Sources last checked November 18, 2026 (America/Los_Angeles). This is not a substitute for advice from the local health department. Procedures involving well caps, pumps, and electricity can be hazardous; the official publications themselves recommend professional help when you are unsure.

Testing for coliform

DOH recommends that private well owners test every year for coliform bacteria and nitrate, because those contaminants “rapidly could affect a person’s health—possibly even with just one drink of water.” Publication 331-349 also lists extra times to test for coliform: an unexplained household illness, a neighbor’s contaminated well or failing septic system, a change in the water’s appearance, taste, or smell, a well-system repair, or flooding. Use an accredited laboratory and the sterile bottle and hold time the lab provides. See Testing and treating well water.

If the sample is unsatisfactory

If coliform is present, 331-349 says you may need to fix the problem by disinfecting the well, installing treatment, or repairing piping, and it tells readers to contact the local health department for advice. A filter marketed for taste or sediment is not a substitute for finding the source of contamination and confirming, with a follow-up lab test, that the water is no longer positive.

Mason County Public Health’s brochure What to Do if Your Drinking Water Sample Test is Unsatisfactory (revised 1/20/2017) explains that an unsatisfactory test means coliform bacteria are present. Those bacteria are common in soil and “indicate that there has either been a breach in the water system or that the sample bottle was contaminated during the sampling process.” Coliform is used as an indicator because it is not possible to test for every disease-causing organism. When coliform is detected, further testing is performed for E. coli, which the brochure describes as fecal bacteria; the lab slip will indicate presence or absence. If the well has been properly disinfected and contamination is still present, the brochure says it is important to identify the source — including the possibility of a defective pressure tank or well casing, a contaminated reservoir, or a contaminated faucet — and it mentions professional treatment such as an automatic chlorinator, ozone, or ultraviolet light, or a replacement water source, without ranking those options.

Official disinfection procedures

Two official procedures were retrieved for this guide. They are not identical, and they should not be blended into a single homemade recipe.

DOH publication 331-242, Emergency Disinfection of Small Water Systems (revised 11/13/2023), is the current statewide publication. It is written for small public water systems (the live DOH page that points to it is in the Group B operations section). It says emergency disinfection should be provided when a system loses pressure, when any part of the system is opened for maintenance or repairs, when a cross-connection event occurs, or when the system is contaminated with coliform bacteria. Before disinfecting after an unsatisfactory routine result, it says to collect all required repeat and Groundwater Rule samples, and to contact regional coliform staff if you are not sure how to proceed. Household bleach used for disinfection “needs to be free of any surfactants, deodorizers, scents, or other modifiers.” If the system does not usually disinfect, notify customers first; high chlorine levels can harm people with unique medical needs, such as kidney dialysis patients, and people with aquariums or fishponds also need to know.

For a well, 331-242’s steps are: calculate the volume of water in the well from casing diameter and the height of standing water (total depth minus static water level); use the bleach table for the desired dose; put the bleach into a five-gallon bucket of water and pour it down the inside of the well; circulate water from a garden hose that has never been used, from the nearest outside faucet, back into the well until you smell chlorine, and rinse the upper casing; disinfect pressure tanks and the rest of the system as the publication describes. Chlorinated water should remain in a pressure tank at least six hours (24 hours preferred). “Never discharge chlorinated water into any water body, wetland, or drainage ditch because it is extremely toxic to fish. You must dechlorinate the water prior to discharge.”

Mason County Public Health’s Disinfecting Your Well brochure (revised 1/20/2017) is written specifically for a private well that has tested positive for coliform. It says the process treats only biological contaminants, not chemical or mineral contaminants such as nitrate. It uses a different bleach-quantity method than 331-242 (a “gallons of bleach needed” calculation and a contact time of at least 8–10 hours, with a follow-up sample after 3–7 days of normal use). Because that brochure is older than 331-242 and the dose method differs, this guide does not reproduce the 2017 formula as if it were the current state procedure. If you are in Mason County, ask Environmental Health which procedure it wants you to follow today, and read the official brochure: Disinfecting Your Well. Residents of other counties should ask their local health department. The current DOH tables are reproduced below, with a link to the full publication.

DOH well-volume and bleach tables (331-242)

The following figures are copied from DOH publication 331-242 (revised 11/13/2023), retrieved from the current official PDF at doh.wa.gov/sites/default/files/2026-10/331-242.pdf. Use the publication itself for pressure-tank and storage-tank steps, the notes on the tables, and the equations if you need a volume that is not listed.

Table 1 — volume of water per vertical foot of well casing:

Table 2 — household-strength 6% bleach needed for well disinfection (the publication also has columns for 8.25% household bleach and 12% commercial bleach):

331-242 notes that American Water Works Association standards assume a component is isolated from the rest of the system and cite much higher chlorine doses: “Do not use high doses if there is a chance that any water system user could consume, or otherwise use, the water.”

After chlorination

331-242 says to wait at least seven days before collecting a coliform sample — or until you know there is no chlorine remaining in the water. If you use a chlorine residual test kit and measure zero free chlorine residual throughout the system sooner than seven days, you may collect coliform samples at that time. Note the residual on the lab slip; a measure of zero is worth noting when the sample follows emergency disinfection. If you are disinfecting in response to an E. coli MCL violation on a public system, the publication says to work with the DOH regional office on timing. Private-well owners should follow the local health department’s instructions for repeat samples.

If a follow-up sample is still unsatisfactory, look for a sanitary defect rather than repeating shock chlorination indefinitely. Mason County’s unsatisfactory-sample brochure makes the same point. Disinfection does not remove nitrate or arsenic; boiling is the wrong response to high nitrate or high manganese, as explained in the testing overview and the manganese guide.

Gaps

Sources